Emm thermal shutdown, Power supply and cooling fan features – Dell POWERVAULT MD1000 User Manual

Page 17

Advertising
background image

About Your System

17

EMM Thermal Shutdown

If critical internal temperatures are reached, the enclosure will be shut down automatically via either a

thermal shutdown command issued by the EMM firmware or via a command from Server Administrator.

Power Supply and Cooling Fan Features

Your storage enclosure supports two integrated, hot-pluggable power supply/cooling fan modules. Each

module contains two separate cooling fans. Both modules must be installed to ensure proper cooling.

The enclosure requires at least three of the cooling fans to operate to avoid overheating.

CAUTION:

A power supply/cooling fan module can be removed from a powered-on enclosure; however, the

enclosure will shut down if overheating occurs.

A power supply/cooling fan module can be replaced without powering down the enclosure. For

information on removing and replacing the modules, see "Removing and Installing the Power

Supply/Cooling Fan Module."
Figure 1-8 shows the power supply/cooling fan module features and LED indicators. Table 1-5 lists the

LED indicator descriptions.

Figure 1-8. Power Supply and Cooling Fan Module LED Features and Indicators

1

DC power LED

3

AC power LED

5

AC power connector

2

Power supply/cooling fan fault

LED

4

cooling fans (2)

6

on/off switch

1

4

6

5

2

3