About Your System

Enclosure Alarms

An audible alarm is activated if any of the fault conditions listed in Table 1-6 occur. If a critical event

occurs, the alarm sounds continuously. If a noncritical event occurs, the alarm sounds every 10 seconds.

NOTE:

The audible alarm is disabled by default. To enable the alarm, you must change the default setting in Server

Administrator. For more information, see Server Administrator Storage Management Service documentation.

NOTE:

It is rare for both EMMs to fail simultaneously. However, if this occurs, the enclosure cannot issue critical

or noncritical event alarms for any enclosure component.

Table 1-5. Power Supply/Cooling Fan Module LED Indicators

LED type

LED color

LED Icon

Function

DC power

Green

On: DC output voltages are within

specifications.
Off: No power, or voltages not within

specifications.

Power

supply/cooling fan

fault

Amber

On: DC output voltages are not within

specifications or one (or both) fans are

in fault.
Off: No fault condition is present.

AC power

Green

On: AC input voltage is within

specifications.
Off: No power, or voltages not within

specifications.

Table 1-6. Critical and Noncritical Events

Critical Events

Noncritical Events

Two or more fan blowers have failed or a power

supply/cooling fan module is not installed.

One power supply has failed.

One or more temperature sensors are in critical range. One cooling fan has failed.

One or more temperature sensors are in warning range.
One EMM has failed.