System Messages

 

System messages appear on the screen to notify you of a possible problem with the system.

Table 2

-4

lists the system messages that can occur and the

probable cause and corrective action for each message.

 

 

 

Table 2-4. System Messages 

 

Orange

 

100-Mbps connection

 

Green

 

10-Mbps connection

NOTE:

If you receive a system message that is not listed in

Table 2

-4

, check the documentation for the application that is running when the message

appears or the operating system's documentation for an explanation of the message and recommended action.

Message

Causes

Corrective Actions

 

A filename cannot contain any of the following characters:

\ / : * ? " < > |

  

 

Do not use these characters in filenames.

 

A required .DLL file was not found

 

The program that you are trying to open

is missing an essential file.

 

Remove and then reinstall the program.

 

See the program documentation for

installation instructions.

 

Alert! Card-cage fan failure.

 

The expansion card fan is faulty or the

fan assembly is not installed correctly.

 

Ensure that the fan assembly is properly

installed. See "

Expansion Card Fan

" in

"Installing System Components."

 

Alert! Chipset heat sink not detected.

 

The chip set heat sink is not properly

installed or is missing.

 

Ensure that the chip set heat sink is properly

installed. See

Figure A

-3

. If the heat sink is

missing, see "Getting Help."

 

Alert! Cover was previously removed.

 

The system was opened.

 

Information only. To reset the chassis

intrusion switch, see "Using the System Setup
Program" in your User's Guide.

 

Alert! CPU 0 fan failure.

 

Alert! CPU 1 fan failure.

 

Specified fan is faulty or the fan assembly

is not installed correctly.

 

Ensure that the processor cooling shroud is

properly installed. See "

Troubleshooting

Fans

" in "Troubleshooting Your System."

 

Alert! Error initializing PCI Express slot n (or bridge).

 

The system encountered a problem while

trying to configure a PCI Express
expansion card

 

See "

Troubleshooting Expansion Cards

" in

"Troubleshooting Your System."

 

Alert! OS Install Mode enabled. Amount of available memory

limited to 256MB

 

The OS Install Mode option in the

System Setup program is set to On. This
limits the amount of available memory to
256 MB because some operating systems
will not complete installation with more
than 2 GB of system memory.

 

After the operating system is installed, enter

the System Setup program and set the OS
Install Mode
option to Off. See your User's
Guide
for details.

 

Alert! Power supply fan failure

 

Faulty power supply.

 

Replace the power supply. See "

Getting

Help

."

 

Alert! Previous fan failure.

 

The fan caused errors the last time the

system was used.

 

Ensure that nothing is blocking the airflow

vents and that all fans are properly installed
and operating correctly.

 

Alert! Processor Cache size mismatch. Install like

processors or one processor. System Halted!

 

Alert! Processor type mismatch. Install like processors or

one processor. System halted!

 

Alert! Processor speed mismatch. Install like processors or

one processor. System halted!

 

Alert! Unsupported processor type detected. System halted!

 

The installed processors are not

identical.

 

Ensure that the processors are identical. See

"

Processor

" in "Installing System

Components."