Faulty hard drive.

l

 

Damaged or improperly connected hard-drive cables.

 

Action

 

 

 

1.

 

Run the appropriate online diagnostic test. See "

Using Server Administrator Diagnostics

" in "Running the System Diagnostics."

2.

 

Enter the System Setup program and verify that the system is configured correctly. See "Using the System Setup Program" in your User's Guide.

3.

 

Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

4.

 

Open the system. See "

Opening the System

."

5.

 

Ensure that the hard-drive interface cable is properly connected between the drive and the system board or controller card.

 

To identify system board connectors, see

Figure A

-3

.

 

To identify controller card connectors, see the documentation that accompanied the controller card.

6.

 

If the hard drive is the boot drive, ensure that the drive is configured and connected properly. See "

Configuring the Boot Drive

" in "Installing Drives."

7.

 

Ensure that the power cable is properly connected to the drive.

8.

 

Close the system. See "

Closing the System

."

9.

 

Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

10.

 

Format and partition the hard drive. See the operating system documentation.

11.

 

If possible, restore the files to the drive.

 

If the problem persists, see "

Getting Help

."

 

Troubleshooting a Hard Drive in a RAID Configuration

 

Problem

l

 

Device driver error.

l

 

Damaged or improperly connected hard-drive cables.

 

Action

 

 

1.

 

Run the appropriate online diagnostic test. See "

Using Server Administrator Diagnostics

" in "Running the System Diagnostics."

2.

 

Restart your system and enter the RAID configuration utility. See the RAID controller documentation.

3.

 

Ensure that the required device drivers are installed and are configured correctly. See the Dell OpenManage Server Assistant for PowerEdge SC

Products CD and the RAID controller's documentation. 

4.

 

Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

5.

 

Open the system. See "

Opening the System

."

CAUTION:

Only trained service technicians are authorized to open the system cover and access any of the components inside the system. See

your System Information Guide for complete information about safety precautions, working inside the computer, and protecting against
electrostatic discharge.

NOTICE:

This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.

NOTE:

If the hard drive is used in a RAID configuration, see "

Troubleshooting a Hard Drive in a RAID Configuration

."

CAUTION:

Only trained service technicians are authorized to open the system cover and access any of the components inside the system. See

your System Information Guide for complete information about safety precautions, working inside the computer, and protecting against
electrostatic discharge.

NOTICE:

This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.