Adding an optional tape library – Dell PowerVault DL2000 User Manual

Page 22

Advertising
background image

Depending on the error condition, automatic disk configuration may or may not be able to proceed. The
following table lists the error conditions that can occur during automatic disk configuration and recommends
you can proceed with automatic disk configuration.

Table 2. Automatic Disk Configuration Error Conditions

Error Condition

Description

Solution/Workaround

Unconfigured physical disks are

not all the same size

One or more physical disks vary in

capacity.
You can proceed with automatic disk

configuration, but, the RAID group is

formed as if all physical disks are the size

of the smallest physical disk. Additional

space on the larger disk(s) is not usable.

To avoid losing storage capacity, all

physical disks must be of the same

size.

Slot 0 is empty (applies to DL2200,

DL2100, DL2000)

If the selected standard configuration is

RAID 5 and a disk is available in slot 0,

automatic disk configuration assigns it as

a global hot spare.
You can proceed with automatic disk

configuration, but, a global hot spare is

not created.

You can add a physical disk in slot 0 at

a later time and automatic disk

configuration assigns that disk as a

global hot spare.

Slot 0 disk size is smaller than

other disks (applies to DL2200,

DL2100, DL2000)

A physical disk in slot 0 to be configured

as a global hot spare is smaller than one

or more physical disks in the remaining

slots in the storage enclosure.
You can proceed with automatic disk

configuration, but, this global hot spare

does not provide failover support for

larger physical disks.

Replace this physical disk with a disk

whose capacity is at least as large as

the remaining physical disks in the

storage enclosure.

The new disk is a SAS disk

Automatic disk configuration is disabled

when any SAS disk drive is detected.
You cannot proceed with automatic disk

configuration.

Either remove the SAS drive or

replace the SAS drive with a SATA

drive.

The new disk is a SATA disk

Automatic disk configuration is disabled

when any SATA disk drive is detected.
You cannot proceed with automatic disk

configuration.

Either remove the SATA drive or

replace the SATA drive with a SAS or

nearline SAS drive.

Adding An Optional Tape Library

For a list of supported tape devices, see the

Dell PowerVault Compatibility Matrix

at dell.com/pvmatrix. For information

about initial setup and configuration of the tape device, see the tape documentation.

NOTE: The tape device is not configured automatically by the CommVault Simpana Backup and Recovery software.

To add a supported tape device to the appliance:

1.

Launch the CommCell Console from the Appliance Console link.

2.

From the Tools menu, select Control Panel.

3.

In the Control Panel, double-click Library and Drive Configuration.

4.

Click Start.

5.

Select:

– SCSI Devices

22

Advertising
This manual is related to the following products: