Error Code

Message Information

5. If the issue persists, see

Getting Help

.

FAN0000

Message

Fan <

number

> RPM is less than the lower warning threshold.

Details

Fan operating speed is out of range.

Action

Remove and reinstall the fan. If the issue persists, see

Getting Help

.

FAN0001

Message

Fan <

number

> RPM is less than the lower critical threshold.

Details

Fan operating speed is out of range.

Action

Remove and reinstall the fan. If the issue persists, see

Getting Help

.

FAN1201

Message

Fan redundancy is lost.

Details

Fan has failed.

Action

Remove and reinstall failed fans or install additional fans.

HWC1001

Message

The <

name

> is absent.

Details

The absent device may be necessary for proper operation. System
functionality may be degraded.

Action

Reinstall or reconnect the hardware.

HWC2003

Message

The storage <

name

> cable is not connected, or is improperly

connected.

Details

The cable may be necessary for proper operation. System
functionality may be degraded.

Action

Check if the cable is present, then reinstall or reconnect.

HWC2005

Message

The system board <

name

> cable is not connected, or is improperly

connected.

Details

The cable may be necessary for proper operation. System
functionality may be degraded.

Action

Check if the cable is present, then reinstall or reconnect.

MEM0000

Message

Persistent correctable memory errors detected on a memory device
at location(s) <

location

>.

Details

This is an early indicator of a possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.