Error Code

Message Information

MEM8000

Message

Correctable memory error logging disabled for a memory device at
location <

location

>.

Details

Errors are being corrected but no longer logged.

Action

Review system logs for memory exceptions. Reinstall memory at
location <

location

>.

PCI1302

Message

A bus time-out was detected on a component at bus <

bus

>

device<

device

> function <

func

>.

Details

System performance may be degraded. The device has failed to
respond to a transaction.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1304

Message

An I/O channel check error was detected.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1308

Message

A PCI parity error was detected on a component at bus
<

bus

>device<

device

>function <

func

>.

Details

System performance may be degraded, PCI device may fail to
operate, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1320

Message

A bus fatal error was detected on a component at bus
<

bus

>device<

device

>function <

func

>.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1342

Message

A bus time-out was detected on a component at slot <

number

>.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1348

Message

A PCI parity error was detected on a component at slot <

number

>.