Error Code

Message Information

PSU1201

Message

Power supply redundancy is lost.

Details

The power supply tries to operate in a degraded state. System
Performance and power redundancy may be degraded or lost.

Action

Check input power. Reinstall the power supply. If the issue persists,
see

Getting Help

.

PSU1204

Message

The power supplies are not redundant. Insufficient resources to
maintain normal operations.

Details

The current power operational mode is non-redundant because of a
power supply exception, a power supply inventory change, or a
system power inventory change.

Action

Check the event log for power supply failures. Review system
configuration and power consumption.

PWR1004

Message

The system performance degraded because power capacity has
changed.

Details

The system may power down or operate in a performance degraded
state.

Action

Check the event log for power supply failures. Review system
configuration and power consumption and upgrade or install power
supplies accordingly.

PWR1005

Message

The system performance degraded because the user-defined power
capacity has changed.

Details

The user-defined power settings have affected system operation.

Action

If unintended, review system configuration changes and power
policy.

PWR1006

Message

The system halted because system power exceeds capacity.

Details

The system halted because system power exceeds capacity.

Action

Review system configuration, upgrade power supplies or reduce
system power consumption.

RFM1008

Message

Failure detected on Removable Flash Media <

name

>.

Details

An error was reported during a SD card read or write.

Action

Reseat the flash media. If the problem persists, see

Getting Help

.