Error Code

Message Information

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PCI1360

Message

A bus fatal error was detected on a component at slot <

number

>.

Details

System performance may be degraded, or system may fail to operate.

Action

Cycle input power, update component drivers, if device is removable,
reinstall the device.

PDR0001

Message

Fault detected on drive <

number

>.

Details

The controller detected a failure on the disk and has taken the disk
offline.

Action

Remove and re-seat the failed disk. If the issue persists, see

Getting

Help

.

PDR1016

Message

Drive <

number

> is removed from disk drive bay <

bay

>.

Details

The controller detected that the drive was removed.

Action

Verify drive installation. Re-seat the failed drive. If the issue persists,
see

Getting Help

.

PST0128

Message

No memory is detected.

Details

System BIOS was unable to detect memory in the system.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

PST0129

Message

Memory is detected, but is not configurable.

Details

System BIOS detected memory, but was unable to configure the
memory for system operation.

Action

Compare system memory installation to supported system memory
configurations.

PSU0001

Message

Power supply <

number

> failed.

Action

Remove and reinstall the power supply. If the issue persists, see

Getting Help

.

PSU0002

Message

A predictive failure detected on power supply <

number

>.

112