Dell PowerVault DR4100 User Manual

Page 117

Advertising
background image

Error Code

Message Information

Details

The chassis was opened while the power was off. System security
may have been compromised.

Action

Close the chassis and verify hardware inventory. Check system logs.

SEL0006

Message

All event logging is disabled.

Details

This message is displayed when all event logging has been disabled
by the user.

Action

If unintended, re-enable logging.

SEL0008

Message

Log is full.

Details

When the event log is full, additional events are not written to the log.
Older events may be overwritten and lost. This message may also
appear if the user disabled event logging.

Action

Backup and clear log.

SEL0012

Message

Could not create or initialize the system event log.

Details

If the system event log fails to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.

Action

Reboot the management controller or iDRAC. Cycle system input
power. If problem persists call support.

SEL1204

Message

An unknown system hardware failure detected.

Details

If the system event log failed to initialize, platform status and failure
events are not captured. Some management software do not report
platform exceptions.

Action

Re-configure system to the minimum supported configuration. If
issues persists, contact support.

TMP0118

Message

The system inlet temperature is less than the lower warning
threshold.

Details

Ambient air temperature is too cool.

Action

Check the system operating environment.

TMP0119

Message

The system inlet temperature is less than the lower critical threshold.

Details

Ambient air temperature is too cool.

117