Dell PowerVault DR4100 User Manual

Page 9

Advertising
background image

Hard-drive indicator

Condition

Corrective Action

4. If the hard drives are configured in a RAID array, restart the

system and enter the host adapter configuration utility

program.

Electrical indicator

Condition

Corrective Action

The indicator blinks
amber if the system
experiences an
electrical error (for
example, voltage out
of range, or a failed
power supply or
voltage regulator).

See the System Event Log or

System Messages

for the specific

issue. If it is due to a problem with the power supply, check the LED
on the power supply. Re-seat the power supply by removing and
reinstalling it. If the problem persists, see

Getting Help

.

Temperature indicator

Condition

Corrective Action

The indicator blinks
amber if the system
experiences a
thermal error (for
example, a
temperature out of
range or fan failure).

Ensure that none of the following conditions exist:

A cooling fan is removed or has failed.

System cover, cooling shroud, EMI filler panel, memory-

module blank, or back-filler bracket is removed.

Ambient temperature is too high.

External airflow is obstructed.

See

Getting Help

.

Memory indicator

Condition

Corrective Action

The indicator blinks
amber if a memory
error occurs.

See the system event log or system messages for the location of the
failed memory. Reinstall the memory device. If the problem persists,
see

Getting Help

.

9