Dell Acceleration Appliances for Databases User Manual

Page 119

Advertising
background image

--exclude

or

–e

<format>

Exclude one or more of the following element types from the graph:

boot_drives

,

boot_raids

,

bus

,

chassis

,

cluster

,

cna

,

cpu

,

drive

,

fan

,

inigroup

,

initiator

,

lun

,

node

,

numa

,

pool

,

port

,

profile

,

psu

,

raid

,

snmp

,

software

,

target

,

temp

,

volume

--from

<domaintype> Specify the start of a range of elements. See the above list for the

--exclude

option.

--to

<domaintype> Specify the end of a range of elements. See the above list for the

-

-exclude

option.

--browse

or

–b

Displays the graph in a browser, if available on your platform.

--input-file

<file> Load configuration from a file.

–-node

or

-n

<address(es)>

Issue this command to one or more nodes in the cluster.

--cluster

Issue this command to all nodes in the cluster.

(See

help –-all

for details on all other options.)

Arguments

configuration

Configuration value to be used, either as a String (XML), a Domain, a
DomainSet, or a ResultMap

Example

This traverses all nodes in the cluster to gather configuration elements (in parallel) and outputs
them to the mychart.jpg file.

> view:graph --cluster --parallel --format jpg --output mychart.jpg

The example below (enhanced) shows a sample graph from a clustered configuration (HA).

119