background image

About Your System

27

DIMM

configuration on

each CPU should

match.

Invalid memory
configuration on a
dual-processor system.
The memory module
configuration for each
processor must be identical.

Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module
Installation Guidelines" on
page 84.

Embedded NICx and

NICy:

OS NIC=<ENABLED

|DISABLED>,

Management

Shared NIC=

<ENABLED

|DISABLED>

The OS NIC interface is set
in BIOS. The Management
Shared NIC interface is set
in management tools.

Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC" on
page 131.

Error 8602 -

Auxiliary Device

Failure. Verify

that mouse and

keyboard are

securely

attached to

correct

connectors.

Mouse or keyboard cable is
loose or improperly
connected.

Reseat the mouse or
keyboard cable.

Defective mouse or keyboard. Ensure that the mouse or

keyboard is operational.
See "Troubleshooting a USB
Device" on page 130.

Gate A20 failure

Faulty keyboard controller;
faulty system board.

See "Getting Help" on
page 155.

Invalid

configuration

information -

please run SETUP

program.

An invalid system
configuration caused a
system halt.

Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and UEFI Boot Manager" on
page 45.

Invalid PCIe card

found in the

Internal_Storage

slot!

The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.

Remove the PCIe expansion
card and install the
integrated storage controller
in the dedicated slot.

Message

Causes

Corrective Actions