Running the dell diagnostics, Running the dell diagnostics -4, 5xqqlqjwkh'hoo'ldjqrvwlfv – Dell Inspiron 3500 User Manual
Page 34

3-4
Dell Inspiron 3500 Portable Computer Service Manual
5XQQLQJWKH'HOO'LDJQRVWLFV
&$87,21 7R SUHYHQW GDPDJH WR WKH RULJLQDO GLDJQRVWLFV GLVNHWWH
DOZD\V XVH D EDFNXS FRS\ RI WKH GLDJQRVWLFV GLVNHWWH ZKHQ VHUYLFLQJ
D XVHU·V FRPSXWHU 'HOO UHFRPPHQGV WKDW XVHUV PDNH VHYHUDO FRSLHV
RI WKLV GLVNHWWH WR HQVXUH WKDW RQH LV DOZD\V DYDLODEOH
The Dell Diagnostics contains tests that aid in troubleshooting the computer.
The diagnostics diskette contains the following test groups:
RAM — Tests the main memory
System Set — Tests the primary functions of the system board
Video — Tests the video subsystem
Keyboard — Tests the keyboard subsystem
Mouse — Tests the mouse/touch pad subsystem
Diskette Drives — Tests the diskette drive subsystem
IDE (ATA/ATAPI) Devices — Tests an IDE hard-disk drive or a CD-ROM or
DVD-ROM drive subsystem
Shadow RAM failed
at offset:
nnnn
Shadow RAM failed at
address
nnnn.
Faulty or improperly
seated memory mod-
ule. Faulty system
board.
System battery is
dead—Replace and
run Setup
CMOS battery dead.
Faulty CMOS battery or
system board.
System cache
error—cache
disabled
The primary cache
internal to the micro-
processor has failed.
Faulty microprocessor.
System CMOS
checksum bad—run
Setup
The BIOS has been
updated. CMOS has
been corrupted or mod-
ified, possibly by an
application program
that changes data
stored in CMOS.
BIOS has been
updated. Verify correct
CMOS settings, save,
and exit.
System RAM failed
at offset:
nnnn
System RAM failed at
address
nnnn in the
64-KB block at which
the error was detected.
Faulty or improperly
seated memory mod-
ule. Faulty system
board.
System timer
error
A chip on the system
board may be malfunc-
tioning.
Faulty system board.
7DEOH 6\VWHP (UURU 0HVVDJHV FRQWLQXHG
0HVVDJH
'HILQLWLRQ
3UREDEOH &DXVHV