Dell PowerEdge R310 User Manual

Page 32

Advertising
background image

32

About Your System

E1810

Hard drive ##

fault. Review

& clear SEL.

The specified hard drive
has experienced a fault.

See "Troubleshooting a
Hard Drive" on page 158.

E1812

Hard drive ##

removed. Check

drive.

The specified hard
drive has been removed
from the system.

Information only.

E1920

iDRAC6 Upgrade

Failed.

optional iDRAC6
upgrade has failed.

See "Getting Help" on
page 169.

E1A14

SAS cable A

failure. Check

connection.

SAS cable A is missing
or bad.

Reseat the cable. If the
problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 169.

E1A15

SAS cable B

failure. Check

connection.

SAS cable B is missing
or bad.

Reseat the cable. If the
problem persists,
replace cable.

If the problem persists,
see "Getting Help" on
page 169.

E1A1D

Control panel

USB cable not

detected.

Check cable.

USB cable to the control
panel is missing or bad.

Reseat the cable. If the
problem persists, replace
cable.

If the problem persists,
see "Getting Help" on
page 169.

E2010

Memory not

detected.

Inspect DIMMs.

No memory was detected
in the system.

Install memory or reseat
memory modules. See
"Troubleshooting System
Memory" on page 153.

E2011

Memory

configuration

failure.

Check DIMMs.

Memory detected, but is
not configurable.
Error detected during
memory configuration.

See "Troubleshooting
System Memory" on
page 153.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

R310HOM.book Page 32 Thursday, March 4, 2010 1:03 AM