Removing lcd status messages (optional) – Dell PowerEdge R310 User Manual

Page 37

Advertising
background image

About Your System

37

Solving Problems Described by LCD Status Messages (Optional)

The code and text on the LCD can often specify a very precise fault condition
that is easily corrected. For example, if the code E1418

CPU_1_Presence

appears, you know that a microprocessor is not installed in socket 1.
In contrast, you might be able to determine the problem if multiple related
errors occur. For example, if you receive a series of messages indicating
multiple voltage faults, you might determine that the problem is a failing
power supply.

Removing LCD Status Messages (Optional)

For faults associated with sensors, such as temperature, voltage, fans, and so
on, the LCD message is automatically removed when that sensor returns to a
normal state. For example, if temperature for a component goes out of range,
the LCD displays the fault; when the temperature returns to the acceptable
range, the message is removed from the LCD. For other faults, you must take
action to remove the message from the display:

W1627

Power required

> PSU wattage.

Check PSU and

config.

The system configuration
requires more power
than what the power
supply can provide.

Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

W1628

Performance

degraded.

Check PSU and

system

configuration.

The system configuration
requires more power
than what the power
supply can provide, but it
can boot if throttled.

Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the

Glossary at

support.dell.com/manuals.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

R310HOM.book Page 37 Thursday, March 4, 2010 1:03 AM

Advertising