Dell PowerEdge R310 User Manual

Page 43

Advertising
background image

About Your System

43

Memory set to

minimum

frequency.

The memory frequency may
be intentionally set lower for
power conservation.

If not an intentional setting,
check any other system
messages for possible causes.

The current memory
configuration may support
only the minimum frequency.

Ensure that your memory
configuration supports the
higher frequency.
See "General Memory
Module Installation
Guidelines" on page 106.

Memory tests

terminated by

keystroke.

POST memory test was
terminated by pressing the
spacebar.

Information only.

MEMTEST lane

failure detected

on

x.

Invalid memory
configuration. Mismatched
memory modules are
installed.

Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 106.

No boot device

available.

Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.

Use a bootable USB key,
optical drive, or hard drive.
If the problem persists,
see "Troubleshooting an
Optical Drive" on page 156,
"Troubleshooting a USB
Device" on page 146,

"Troubleshooting an Internal
USB Key" on page 155, and
"Troubleshooting a Hard
Drive" on page 158.
See "Using the System Setup
Program and UEFI Boot
Manager" on page 53 for
information on setting the
order of boot devices.

Table 1-3.

System Messages (continued)

Message

Causes

Corrective Actions

R310HOM.book Page 43 Thursday, March 4, 2010 1:03 AM

Advertising