Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The optional iDRAC6
has hung.

The optional iDRAC6 was
remotely reset while system
was booting.

After AC recovery, the
optional iDRAC6 takes
longer than normal to boot.

Remove AC power to the
system for 10 seconds and
restart the system.

Alert! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The system configuration
of processor,
memory modules,
and expansion cards may
not be supported by the
power supplies.

If any system components
were just upgraded,
return the system to the
previous configuration.
If the system boots without
this warning, then the
replaced component(s) are
not supported with this
power supply. If Energy
Smart power supplies are
installed, replace them with
High Output power supplies
to use the components.
See "Power Supplies" on
page 125.

Alert! System

fatal error

during previous

boot.

An error caused the system to
reboot.

Check other system
messages for additional
information for possible
causes.