33

E2111 SBE log

disabled on
DIMM ##.
Reseat DIMM.

The system BIOS has

disabled memory

single-bit error (SBE)

logging and will not log

anymore SBEs until the

system is rebooted. “##”

represents the memory

module implicated by

the BIOS.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Troubleshooting

System Memory" on

page 145.

I1910 Intrusion

detected.
Check chassis
cover.

System cover has been

removed.

Information only.

I1911 LCD Log Full.

Check SEL to
review all
Errors.

LCD overflow message.

A maximum of ten error

messages can display

sequentially on the LCD.

The eleventh message

instructs the user to check

the SEL for details on the

events.

Check the SEL for details

on the events.
Remove AC power to the

system for 10 seconds or

clear the SEL.

I1912 SEL full.

Review & clear
log.

The SEL is full of events

and is unable to log any

more.

Check the SEL for details

on the events, then clear

the SEL.

I1920 iDRAC6 Upgrade

Successful.

iDRAC6 has been

upgraded successfully.

Information only.

W1627 Power required

> PSU wattage.
Check PSU and
config.

The system configuration

requires more power

than what the power

supply can provide.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supplies, and then

restart the system.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book.book Page 33 Tuesday, September 7, 2010 8:45 PM