Dell DX6004S User Manual

Page 40

Advertising
background image

40

About Your System

Memory set to
minimum
frequency.

The memory frequency may

be intentionally set lower for

power conservation.

If not an intentional setting,

check any other system

messages for possible causes.

The current memory

configuration may support

only the minimum frequency.

Ensure that your memory

configuration supports the

higher frequency.

See "General Memory

Module Installation

Guidelines" on page 98.

Memory tests
terminated by
keystroke.

POST memory test was

terminated by pressing the

spacebar.

Information only.

MEMTEST lane
failure detected
on x.

Invalid memory

configuration. Mismatched

memory modules are

installed.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module Installation

Guidelines" on page 98.

No boot device
available.

Faulty or missing optical

drive subsystem, hard drive,

or hard drive subsystem, or

no bootable USB key

installed.

Use a bootable optical drive,

or hard drive. If the problem

persists,

see "Troubleshooting an

Optical Drive" on page 147,

"Troubleshooting a USB

Device" on page 138, and

"Troubleshooting a Hard

Drive" on page 149.

See "Using the System Setup

Program and UEFI Boot

Manager" on page 51 for

information on setting the

order of boot devices.

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

book.book.book Page 40 Tuesday, September 7, 2010 8:45 PM