About Your System

Thermal sensor
not detected on
x.

A memory module without a

thermal sensor is installed in

the specified memory slot.

Replace the memory

module. See "System

Memory" on page 97.

Time-of-day
clock stopped.

Faulty battery or faulty chip. See "Troubleshooting the

System Battery" on page 142.

Time-of-day not
set - please run
SETUP program.

Incorrect Time or Date

settings; faulty system

battery.

Check the Time and Date

settings. See "Using the

System Setup Program and

UEFI Boot Manager" on

page 51. If the problem

persists, replace the system

battery. See "System Battery"

on page 122.

Timer chip
counter 2 failed.

Faulty system board.

See "Getting Help" on

page 161.

TPM
configuration
operation
honored. System
will now reset.

A TPM configuration

command has been entered.

The system will reboot and

execute the command.

Information only.

TPM
configuration
operation is
pending. Press
(I) to Ignore OR
(M) to Modify to
allow this change
and reset the
system.
WARNING:
Modifying could
prevent
security.

This message displays during

system restart after a TPM

configuration command has

been entered. User

interaction is required to

proceed.

Enter I or M to proceed.

TPM failure.

A Trusted Platform Module

(TPM) function has failed.

See "Getting Help" on

page 161.