Installing Enclosure Components

4 Rotate the carrier handle to the closed position while continuing to push

the carrier into the slot.

The status LED indicator (see Table 1-3 for description) will display a
steady green if the physical disk is inserted properly. If the indicator is not
illuminated, see "Troubleshooting SAS Physical Disks" on page 76.

NOTE:

At least two physical disks must be installed in the enclosure.

Removing and Installing a RAID Controller
Module

The enclosure contains two RAID controller modules. Both are hot-pluggable
and can be removed and installed independently without shutting down the
enclosure.

NOTICE:

Removing a module is not recommended while data traffic involving that

module is occurring. Although RAID controller modules are hot-pluggable, data loss
could result from removing a module involved in data traffic.

CAUTION:

Always wear a wrist grounding strap when handling equipment with

static-sensitive components. See your Product Information Guide for safety
information.

Removing a RAID Controller Module

1 Push up on the release tab on the left side of the module (see Figure 3-4).
2 At the same time, pull out on the release lever. When the lever is pulled

out, the controller module partially ejects from the enclosure.

3 Remove the module from the enclosure and place it on a flat, secure

surface.

NOTICE:

To avoid damage to the sensitive EMI contacts on the bottom of the

controller module, do not stack or place it on a hard surface.

Advertising