Dell PowerEdge 6850 User Manual

Page 30

Advertising
background image

installed expansion card.

"Troubleshooting Your System."

PCIe Degraded Link Width Error: Embedded

Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Actual Link Width is n

Faulty or improperly
installed PCIe card.

Reseat the PCIe cards. See "

Expansion Cards

." If the problem persists,

see "

Getting Help

."

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly
installed PCIe card in the
specified slot number.

Reseat the PCIe card in the specified slot number. See "

Expansion

Cards

." If the problem persists, see "

Getting Help

."

PCIe Training Error: Embedded

Bus#nn/Dev#nn/Funcn

Faulty or improperly
installed PCIe card.

Reseat the PCIe cards. See "

Expansion Cards

." If the problem persists,

see "

Getting Help

."

PCIe Training Error: Slot n

Faulty or improperly
installed PCIe card in the
specified slot number.

Reseat the PCIe card in the specified slot number. See "

Expansion

Cards

." If the problem persists, see "

Getting Help

."

Plug & Play Configuration Error

Error encountered in
initializing PCI device;
faulty system board.

Install the NVRAM_CLR jumper and reboot the system. See

Figure A

-2

for

jumper location. Check for a BIOS update. If the problem persists, see
"

Troubleshooting Expansion Cards

" in "Troubleshooting Your System." If

the problem persists, see "

Getting Help

."

Read fault

Requested sector not found

Faulty diskette, diskette
drive, optical drive, or hard
drive.

Replace the diskette. Ensure that the diskette, optical, and hard-drive
cables are properly connected. See "

Troubleshooting a Diskette Drive

,"

"

Troubleshooting an Optical Drive

," or "

Troubleshooting SCSI Hard

Drives

" in "Troubleshooting Your System" for the appropriate drive(s)

installed in your system.

Remote Configuration update attempt failed

System could not
implement Remote
Configuration request.

Retry Remote Configuration.

ROM bad checksum = address

Faulty or improperly
installed expansion card.

Remove and reseat the expansion cards. See "

Troubleshooting

Expansion Cards

" in "Troubleshooting Your System."

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard
drive.

Replace the diskette. If the problem persists, see "

Troubleshooting SCSI

Hard Drives

" in "Troubleshooting Your System" for the appropriate drive

installed in your system.

Shutdown failure

Shutdown test failure.

Ensure that all memory modules are properly installed. See
"

Troubleshooting System Memory

" in "Troubleshooting Your System." If

the problem persists, see "

Getting Help

."

Spare bank enabled

Memory spare bank
enabled.

You can enable memory spare bank using the System Setup program if
the memory is configured to support this feature. For more information,
see "

General Memory Module Installation Guidelines

" in "Installing

System Components," and "Using the System Setup Program" in your
User's Guide.

The amount of system memory has changed.

Faulty memory module.

Information only, if you
have changed the memory
configuration.

See "

Troubleshooting System Memory

" in "Troubleshooting Your

System." If the problem persists, see "

Getting Help

."

Time-of-day clock stopped

Faulty battery; faulty
system board.

See "

Troubleshooting the System Battery

" in "Troubleshooting Your

System." If the problem persists, see "

Getting Help

."

Time-of-day not set - please run SETUP program

Incorrect Time or Date
settings; faulty system
battery.

Check the Time and Date settings See "Using the System Setup
Program" in your User's Guide. If the problem persists, see
"

Troubleshooting the System Battery

" in "Troubleshooting Your System."

Timer chip counter 2 failed

Faulty system board.

See "

Getting Help

."

Unsupported RAID key detected.

A RAID key intended for
use with another system is
installed.

Replace the RAID key.

Unexpected interrupt in protected mode

Faulty or improperly
installed memory modules
or faulty system board.

Ensure that all memory modules are properly installed. See "

General

Memory Module Installation Guidelines

" in "Installing System

Components." If the problem persists, see "

Troubleshooting System

Memory

" in "Troubleshooting Your System." If the problem persists, see

"

Getting Help

."

Unsupported CPU combination

Mismatched processors are
installed.

Replace a microprocessor so that both microprocessors match. See
"

Processor

" in "Installing System Components."

Processor is not supported
by the system.

Check for a BIOS update using the Dell Support website at
support.dell.com. If the problem persists, install a supported processor.
See "

Processor

" in "Installing System Components."

Unsupported CPU stepping detected

Processor is not supported
by the system.

Check for a BIOS update using the Dell Support website at
support.dell.com. If the problem persists, install a supported processor.
See "

Processor

" in "Installing System Components."

Utility partition not available

<F10> key was pressed
during POST, but no utility
partition exists on the boot
hard drive.

Create a utility partition on the boot hard drive. See "Using the Dell
OpenManage Server Assistant CD" in your User's Guide.

Warning: Detected mode change from RAID to SCSI

x of the embedded RAID subsystem.

Type of controller has
changed from optional RAID
to SCSI since previous
system boot.

Back up information on the hard drives before changing the type of
controller used with the drives.

Warning: Detected mode change from SCSI to RAID

Type of controller has

Back up information on the hard drives before changing the type of

Advertising