System beep codes – Dell PowerEdge 6850 User Manual

Page 31

Advertising
background image

 

System Beep Codes

If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the problem.

If a beep code is emitted, write down the series of beeps and then look it up in

Table 2

-9

. If you are unable to resolve the problem by looking up the meaning

of the beep code, use system diagnostics to identify the possible cause. See "

Running the System Diagnostics

" for more information. If you are still unable to

resolve the problem, see "

Getting Help

."

 

 

Table 2-9. System Beep Codes 

x of the embedded RAID subsystem.

changed from SCSI to
optional RAID since
previous system boot.

controller used with the drives.

Warning! No microcode update loaded for

processor n

Unsupported processor.

Update the BIOS firmware using the Dell Support website at
support.dell.com.

Write fault

Write fault on selected drive

Faulty diskette, diskette
drive, optical drive, hard
drive.

Replace the diskette. Ensure that the diskette drive, optical drive, and
hard- drive cables are properly connected. See "

Troubleshooting a

Diskette Drive

," "

Troubleshooting an Optical Drive

," or "

Troubleshooting

SCSI Hard Drives

" in "Troubleshooting Your System" for the appropriate

drive(s) installed in your system.

NOTE:

If the system boots without a keyboard, mouse, or monitor attached, the system does not issue beep codes related to those peripherals.

CAUTION:

Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as

authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not
authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

 

Code

 

Cause

 

Corrective Action

1-1-2

CPU register test failure

See "

Troubleshooting the Microprocessors

" in "Troubleshooting Your System."

1-1-3

CMOS write/read failure; faulty system board

Faulty system board. See "

Getting Help

."

1-1-4

BIOS error

Reflash the BIOS.

1-2-1

Programmable interval-timer failure; faulty system
board

Faulty system board. See "

Getting Help

."

1-2-2

DMA initialization failure

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

1-2-3

DMA page register write/read failure

1-3-1

Main-memory refresh verification failure

1-3-2

No memory installed

1-3-3

Chip or data line failure in the first 64 KB of main 
memory

1-3-4

Odd/even logic failure in the first 64 KB of main 
memory

1-4-1

Address line failure in the first 64 KB of main 
memory

1-4-2

Parity failure in the first 64 KB of main memory

1-4-3

Fail-safe timer test failure

1-4-4

Software NMI port test failure

2-1-1
through
2-4-4

Bit failure in the first 64 KB of main memory

3-1-1

Slave DMA-register failure

Faulty system board. See "

Getting Help

."

3-1-2

Master DMA-register failure

3-1-3

Master interrupt-mask register failure

3-1-4

Slave interrupt-mask register failure

3-2-2

Interrupt vector loading failure

3-2-4

Keyboard-controller test failure

3-3-1

CMOS failure

3-3-2

System configuration check failure

3-3-3

Keyboard controller not detected

3-3-4

Video memory test failure

3-4-1

Screen initialization failure

3-4-2

Screen-retrace test failure

3-4-3

Video ROM search failure

4-2-1

No timer tick

Faulty system board. See "

Getting Help

."

 

4-2-2

Shutdown test failure

Advertising