Installing drives, Installing scsi hard drives, Before you begin – Dell PowerEdge 6850 User Manual

Page 74: Installing a scsi hard drive

Advertising
background image

Back to Contents Page

 

Installing Drives

Dell™ PowerEdge™ 6850 Systems Installation and Troubleshooting Guide 

  

Installing SCSI Hard Drives

  

Installing a Diskette Drive

  

Installing an Optical Drive

  

Connecting an External SCSI Tape Drive

  

Configuring the Boot Drive

  

SCSI Backplane Daughter Card

  

Activating the Optional Integrated RAID Controller

  

Installing a RAID Controller Card

  

SCSI Hard-Drive Cabling Guidelines


Your system features five standard internal hard-drive bays that accommodate up to five 3.5-inch SCSI hard drives. Systems with an optional RAID controller
card or optional ROMB support hot-plug SCSI drive operation.

The system's peripheral bay can accommodate a removable drive carrier that supports an optional diskette drive and optional optical drive.

 

Installing SCSI Hard Drives

Figure 7

-1

shows the SCSI ID numbers of the five standard drive bays.

 

Figure 7-1. Hard-Drive SCSI ID Numbers

 

Before You Begin

SCSI hard drives are supplied in special drive carriers that fit in the hard-drive bays.

You may need to use different programs than those provided with the operating system to partition and format SCSI hard drives.

When you format a high-capacity SCSI hard drive, allow enough time for the formatting to be completed. Long format times for these drives are normal. A 9-GB
hard drive, for example, can take up to 2.5 hours to format.

 

Installing a SCSI Hard Drive

 

1.

If the system does not have an optional RAID controller card or optional integrated ROMB, shut down the system.

 

2.

Remove the front bezel, if attached. See "

Opening the System

" in "Troubleshooting Your System."


 

3.

Open the hard-drive handle. See

Figure 7

-2

.

 

Figure 7-2. Installing a SCSI Hard Drive

NOTICE:

Before attempting to remove or install a drive while the system is running, see the documentation for the optional RAID controller card or

optional ROMB to ensure that the host adapter is configured correctly to support hot-plug drive removal and insertion.

NOTE:

It is recommended that you use only drives that have been tested and approved for use with the SCSI backplane board.

NOTICE:

Do not turn off or reboot your system while the drive is being formatted. Doing so can cause a drive failure.

NOTICE:

Hot-plug drive installation is not supported for systems without an optional RAID controller card or optional ROMB.

Advertising