Changing the systemgroup configuration parameters, Setting snmpv1 configuration parameters, Setting snmpv3 configuration parameters – Dell POWEREDGE M1000E User Manual

Page 209

Advertising
background image

Web Tools Administrator’s Guide

181

53-1002756-01

SNMP configuration

15

1. Open the Switch Administration window as described in

“Opening the Switch Administration

window”

on page 31.

2. Select the SNMP tab.

3. Select a trap level for a recipient from the corresponding Trap Level menu in the SNMPv1 and

SNMPv3 sections.

The level you select identifies the minimum event level that prompts a trap.

NOTE

Adding or editing the user name can be done only through the CLI and by selecting a user
name from the User Name menu in the SNMPv3 section.

4. Click Apply.

Changing the systemGroup configuration parameters

To change the systemGroup configuration parameters, perform the following steps.

1. Open the Switch Administration window as described in

“Opening the Switch Administration

window”

on page 31.

2. Select the SNMP tab.

3. Enter a contact name, description, and location in the SNMP Information section.

4. Optional: Select the Enable Authentication Trap check box to allow authentication traps to be

sent to the reception IP address.

5. Click Apply.

Setting SNMPv1 configuration parameters

To set SNMPv1 configuration parameters, perform the following steps.

1. Open the Switch Administration window as described in

“Opening the Switch Administration

window”

on page 31.

2. Select the SNMP tab.

3. Double-click a community string in the SNMPv1 section and enter a new community string.

4. Double-click a recipient IP address in the SNMPv1 section and enter a new IP address.

5. Click Apply.

Setting SNMPv3 configuration parameters

NOTE

The port number is not included.

To set SNMPv3 configuration parameters, perform the following steps.

1. Open the Switch Administration window as described in

“Opening the Switch Administration

window”

on page 31.

2. Select the SNMP tab.