System Messages

 

System messages appear on the console during POST to notify you of a possible problem with the system. If you are performing console redirection, system
messages will appear on the console.

Table 2

-3

lists the system messages that can occur and the probable cause and corrective action for each message.

 

 

 

Table 2-3. System Messages 

NOTE:

If you receive a system message that is not listed in

Table 2

-3

, check the documentation for the application program that is running when the

message appears or the operating system's documentation for an explanation of the message and recommended action.

Message

Causes

Corrective Actions

 

Address mark not found

 

Faulty diskette/CD-drive subsystem

or hard-drive subsystem.

 

Ensure that the diskette/CD-drive subsystem and hard drives are properly installed. If the

problem persists, replace the diskette/CD-drive subsystem. See "

Removing the CD and

Diskette Drives

" in "Installing Drives." If the problem persists, replace the faulty hard

drive. See "

Hard Drives

" in "Installing Drives." If the problem persists, see "

Getting Help

."

 

Alert! Cover was

previously removed!

 

The chassis has been opened.

 

Information only.

 

Alert! CPU fan was not

detected.

 

Specified fan is missing, faulty, or

improperly installed. See

Figure 5

-3

to

identify the fans.

 

Ensure that the specified fan is properly installed. If the problem persists, replace the fan.

See "

Fan Assemblies

" in "Installing System Components."

 

Alert! Memory fan was

not detected.

 

Alert! PCI fan was not

detected.

 

Alert! Previous CPU

fan failure.

 

Specified fan failed before last system

startup. See

Figure 5

-3

to identify the

fans.

 

Information only.

 

Alert! Previous Memory

fan failure.

 

Alert! Previous PCI

fan failure.

 

Alert! Previous

voltage failure.

 

Power supply failed before last

system startup.

 

Information only.

 

Alert! Processor

thermal probe failure

detected.

 

Microprocessor fan is missing, faulty,

or improperly installed.

 

Ensure that the processor fan is properly installed. See

Figure 5

-3

for the processor fan

location. If the problem persists, replace the fan. See "

Fan Assemblies

" in "Installing

System Components."

 

Alert! Previous

shutdown due to

Processor thermal

event.

 

Processor fan failed before the last

system startup

 

Information only.

 

Alert! Unsupported

memory

 

Unsupported or faulty memory

module(s).

 

Ensure that all memory modules are properly installed. If the problem persists, replace

the memory module(s). See "

Removing Memory Modules

" and "

Installing Memory Modules

"

in "Installing System Components."

 

Amount of available

memory limited to

256MB!

 

OS Install Mode is enabled in the

System Setup program.

 

Disable OS Install Mode in the System Setup program. See "Using the System Setup

Program" in your User's Guide.

 

Auxiliary device

failure

 

Loose or improperly connected mouse

or keyboard cable; faulty mouse or
keyboard.

 

Replace the mouse. If the problem persists, replace the keyboard.