Dell PowerEdge 650 User Manual

Page 25

Advertising
background image

Non-system disk or

disk error

subsystem; no operating system on
diskette or hard drive.

problem persists, replace the faulty hard drive. See "

Hard Drives

" in "Installing Drives."

 

Not a boot diskette

 

No operating system on diskette.

 

Use a bootable diskette.

 

PCI BIOS failed to

install

 

Loose cables to expansion card(s);

faulty or improperly installed
expansion card.

 

Ensure that all appropriate cables are securely connected to the expansion cards. If the

problem persists, remove and reseat the expansion cards. See "

Expansion Cards

" in

"Installing System Components." If the problem persists, replace the expansion card(s).

 

Plug & Play

Configuration Error

 

Error encountered in initializing PCI

device; faulty system board.

 

Install the NVRAM_CLR jumper and reboot the system. See

Figure A

-2

for jumper location.

Check for a BIOS update. If the problem persists, remove and reseat the expansion cards.
See "

Expansion Cards

" in "Installing System Components." If the problem persists,

replace the expansion card(s). If the problem persists, see "

Getting Help

."

 

Primary drive n not

found

 

Incorrect configuration settings in

System Setup program. Drive set as
Auto, no disk installed.

 

Run the System Setup program to correct the settings. See "Using the System Setup

Program" in your User's Guide.

 

Read fault

 

Requested sector not

found

 

Faulty diskette, diskette/CD-drive

assembly, hard drive, or hard-drive
subsystem.

 

Replace the diskette/CD-drive subsystem. See "

Removing the CD and Diskette Drives

" in

"Installing Drives." If the problem persists, replace the faulty hard drive. See "

Hard Drives

"

in "Installing Drives."

 

Reset failed

 

Improperly connected drive interface

or power cable.

 

Ensure that the interface cable is securely connected between the diskette/CD interposer

board and the backplane board. Ensure that the interface and power cables are securely
connected to the backplane board.

 

ROM bad checksum =

address

 

Faulty or improperly installed

expansion card.

 

Remove and reseat the expansion cards. See "

Expansion Cards

" in "Installing System

Components." If the problem persists, replace the expansion card(s).

 

Secondary drive n not

found

 

Incorrect configuration settings in

System Setup program. Drive set as
Auto, no disk installed.

 

Run the System Setup program to correct the settings. See "Using the System Setup

Program" in your User's Guide.

 

Sector not found

 

Seek error

 

Seek operation failed

 

Faulty diskette or hard drive.

 

Replace the diskette. If the problem persists, replace the hard drive. See "

Hard Drives

" in

"Installing Drives."

 

Shutdown failure

 

Shutdown test failure.

 

Ensure that all memory modules are properly installed. If the problem persists, replace

the memory module(s). See "

Removing Memory Modules

" and "

Installing Memory Modules

"

in "Installing System Components."

 

Time-of-day clock

stopped

 

Faulty battery.

 

Replace the system battery. See "

Replacing the Battery

" in "Installing System

Components."

 

Time-of-day not set -

please run SETUP

program

 

Incorrect Time or Date settings;

faulty system battery.

 

Check the Time and Date settings See "Using the System Setup Program" in your User's

Guide. If the problem persists, replace the system battery. See "

Replacing the Battery

" in

"Installing System Components."

 

Timer chip counter 2

failed

 

Faulty system board.

 

See "

Getting Help

."

 

Unexpected interrupt

in protected mode

 

Faulty or improperly installed memory

modules or faulty system board.

 

Ensure that all memory modules are properly installed. If the problem persists, replace

the memory module(s). See "

Removing Memory Modules

" and "

Installing Memory Modules

"

in "Installing System Components." If the problem persists, see "

Getting Help

."

 

Unsupported CPU

stepping detected

 

Microprocessor is not supported by

the system.

 

Check for a BIOS update. If the problem persists, install a supported microprocessor. See

"

Upgrading the Processor

."

 

Utility partition not

available

 

<F10> key was pressed during POST,

but no utility partition exists on the
boot hard drive.

 

Create a utility partition on the boot hard drive. See "Using the Dell OpenManage Server

Assistant CD" in your User's Guide.

 

 

Firmware is out-of-date.

 

Update the firmware, see "

Getting Help

."

Advertising