Dell PowerEdge 650 User Manual

Page 24

Advertising
background image

Invalid memory

configuration

detected. Potential

corruption exists!

 

Keyboard controller

failure

 

Faulty keyboard controller (faulty

system board).

 

See "

Getting Help

."

 

Keyboard data line

failure

 

Keyboard failure

 

Keyboard stuck key

failure

 

Loose or improperly connected

keyboard cable; faulty keyboard;
faulty keyboard controller.

 

Ensure that the keyboard is properly connected. If the problem persists, replace the

keyboard. If the problem persists, see "

Getting Help

."

 

Memory address line

failure at address,

read value expecting

value

 

Memory double word

logic failure at

address, read value

expecting value

 

Memory odd/even logic

failure at start

address to end address

 

Memory write/read

failure at address,

read value expecting

value

 

Faulty or improperly installed memory

modules, or faulty system board.

 

Ensure that all memory modules are properly installed. If the problem persists, replace

the memory module(s). See "

Removing Memory Modules

" and "

Installing Memory Modules

"

in "Installing System Components." If the problem persists, see "

Getting Help

."

 

Memory allocation

error

 

Faulty application program.

 

Restart the application program.

 

Memory bank population

error!

 

Memory modules are not installed in

decreasing size with the largest size
of memory modules in bank 1; faulty
memory module(s); memory modules
are not installed sequentially.

 

Ensure that the memory modules are properly installed. Ensure that the memory modules

are populated sequentially. See "

Memory Module Installation Guidelines

" in "Installing

System Components." If the problem persists, replace the specified memory modules. See
"

System Memory

" in "Installing System Components."

 

Memory parity

interrupt at address

 

Faulty or improperly installed memory

modules.

 

Ensure that all memory modules are properly installed. If the problem persists, replace

the memory module(s). See "

Removing Memory Modules

" and "

Installing Memory Modules

"

in "Installing System Components."

 

Memory tests

terminated by

keystroke

 

The spacebar was pressed during

POST to terminate the memory test.

 

Information only.

 

No boot device

available

 

Faulty or missing diskette/CD-drive

subsystem, hard drive, or hard-drive
subsystem.

 

 

Check the Integrated Devices configuration settings in the System Setup program. See

"Using the System Setup Program" in your User's Guide. Ensure that either SCSI
Controller
, Diskette Controller, or IDE CD-ROM Controller is enabled. If booting from a
SCSI controller, ensure that the controller is properly connected. If the problem persists,
replace the diskette/CD drive subsystem. See "

Removing the CD and Diskette Drives

" in

"Installing Drives." If the problem persists, replace the faulty hard drive. See "

Hard Drives

"

in "Installing Drives."

 

No boot sector on

hard-disk drive

 

No operating system on hard drive.

 

Check the hard-drive configuration settings in the System Setup program. See "Using the

System Setup Program" in your User's Guide.

 

No timer tick

interrupt

 

Faulty system board.

 

See "

Getting Help

."

 

 

Faulty diskette, diskette/CD-drive

assembly, hard drive, or hard-drive

 

Use a bootable diskette. If the problem persists, replace the diskette/CD-drive

subsystem. See "

Removing the CD and Diskette Drives

" in "Installing Drives." If the