Standalone mode program commands – Detex DTX-2300 User Manual

Page 20

Advertising
background image

Prox.pad Installer Guide

Document # 6-055678 X2

Page 20 of 32

Standalone Mode Program Commands

If you need to change any of the program default values or wish to add functions, fi rst enter program mode and then enter
the desired program command. Defaults are in bold.

Note: The master code must be changed prior to performing any programming on the prox.pad unit. When programming
users, the term user location refers to the place in the units memory that the user is stored.

Action Desired

Press

Details

Enter Program Mode

99 # (Master Code)

Yellow LED blinks slowly

Change master code

1 # (new code)

(repeat code)

Ex: 1 # 4321

✱ 4321 ✱

Enter new code

Set main relay time

11 # tt # 0 #

✱ ✱

tt=1-99 seconds (default =
5 seconds)

Set AUX relay output

15 # output # 0 #

✱ ✱

0=disabled
1=shunt (default)
2=forced door
3=propped door

Delete Users

user location #

✱ ✱

Set/clear standard option

30 # option # s/c #

✱ ✱

See Chart below

Option Set

Clear

0 — Audio Keypress Feedback

1 = Enabled

0 = Disabled

1 — Visual Keypress Feedback

1 = Enabled

0 = Disabled

2 — Auto Entry

0 = Disabled

1 = Enabled

3 — Operating Mode

0 = Standalone

1 = Front End

4 — Facility Code Access

0 = Disabled

1 = Enabled

5 — Forced Door Audio Alert

0 = Disabled

1 = Enabled

6 — Propped Door Audio Alert

0 = Disabled

1 = Enabled

7 — Internal REX Switch

0 = Disabled

1 = Enabled

8 — Daylight Savings Time Format

0 = US

1 = European

13 — Daylight Savings Time

0 = Disabled

1 = Enabled

14 — Prox Card Anti-Passback Select

0 = Disabled

1 = Enabled

18 — Invalid PIN Lockout Select

0 = Disabled

1 = Enabled

19 — Invalid PIN Lockout Action

0 = Timed Lockout

1 = Forced Door Output

Print User List

25 # 0 # 0 #

✱ ✱

Print User List
(From Certain User Location)

25 # 0 # start user #

✱ ✱

Advertising