Detex DTX-2300 User Manual

Page 21

Advertising
background image

Prox.pad Installer Guide

Document # 6-055678 X2

Page 21 of 32

Action Desired

Press

Details

Change Platform Parameters

32 # parameter # value #

✱ ✱

See Chart Below

Parameter Value

2 — 26 Bit Facility Code

0 — 255; (Default = 1)

Note: IEI Cards are Facility Code 11

3 — Process Card Time

2 — 240; 1/4 sec. Increments

(Defaults to 4 = 1 sec.)

4 — Invalid PIN Lockout Attempts

1 — 50 (Default = 5)

5 — Invalid PIN Lockout Duration

1 — 255; 5 sec. increments;)

(Defaults to 60 = 5 Minutes)

Set System Time

41 # hhmm # 0 #

✱ ✱

hhmm=hour/minute (24 Hour Format)

Set System Date

42 # mmddyy # dow #

✱ ✱

mmddyy=month, date, year; dow=day
of week, 1=Sunday

Set Propped Door Time

44 # ttt # 0 #

✱ ✱

ttt=propped door time, to nearest
10’s seconds, entered as 30-990;
(default=30 secs)

(this sets the time for both Aux Relay
and local sounder)

Set Forced Door Time

45 # ttt # 0 #

✱ ✱

ttt=propped door time, to nearest
10’s seconds, entered as 30-990;
(default=10 secs)

(this sets the time for both Aux Relay
and local sounder)

Reset System Defaults Only

40 # 00000 # 00000 #

✱ ✱

Does not delete users

Delete Entire Memory and Reset
System Defaults

46 # 00000 # 00000 #

✱ ✱

Deletes all memory including users

Program User — Code Only

50 # user type # user location #

code

repeat code

User Types:
0-Toggle/latch lock
1-Normal access
2-Log Dump
3-Lockout

Program User — Code AND Card By
Presenting Card

50 # user type # user location #
code

repeat code ✱ ✱ <present

card>

User Types:
0-Toggle/latch lock
1-Normal access
2-Log Dump
3-Lockout

Advertising