Wiegand programming commands – Detex DTX-2300 User Manual

Page 26

Advertising
background image

Prox.pad Installer Guide

Document # 6-055678 X2

Page 26 of 32

Wiegand Programming Commands

If you need to change any of the program default values or wish to add functions, fi rst enter program mode and then enter
the desired program command. Defaults are in bold.

Note: The master code must be changed prior to performing any programming on the prox.pad unit.

Action Desired

Press

Details

Enter Program Mode

99 # (Master Code)

Yellow LED blinks slowly

Change master code

1 # (new code)

(repeat code)

Ex: 1 # 4321

✱ 4321

Enter new code

Set/clear standard option

30 # option # s/c #

✱ ✱

See Chart Below

Option Set

Clear

0 — Audio Keypress Feedback

1 = Enabled

0 = Disabled

1 — Visual Keypress Feedback

1 = Enabled

0 = Disabled

2 — Auto Entry

0 = Disabled

1 = Enabled

3 — Operating Mode

0 = Standalone

1 = Front End

9 — Wiegand Red LED Enable

0 = Disabled

1 = Enabled

10 — Wiegand Red LED Active State

0 = Low

1 = High

11 — Wiegand Green LED Enable

0 = Disabled

1 = Enabled

12 — Wiegand Green LED Active State

0 = Low

1 = High

15 — Front End Mode Select

0 = Wiegand Front End

1 = Secured Series Front End

Change Platform Parameters

32 # parameter # value #

✱ ✱

See Chart Below

Parameter Value

0 — Wiegand Pulse Width

1 — 255; 20µS increments;

(Defaults to 8 = 160µS)

1 — Wiegand Interpulse Spacing

1 — 255; 20µS increments;

(Defaults to 32 = 640µS)

Delete Entire Memory and Reset
System Defaults

46 # 00000 # 00000 #

✱ ✱

To exit Program mode

Press

Yellow stops fl ashing

Advertising