Secured Series Front End Mode LED Indicators/Sounder

LED/Sounder

Visual/Audible Condition

Description

Yellow LED

Slow blink

Unit is in program mode

Rapid blink

Verify mode is active (checking that the last two values in sequence
match)

Steady

Program error; entry error lockout (no keypress feedback)

Very rapid blink

Memory (eeprom) erase is in progress (command 46)

“Pulsing” rapid blink

Batch program of cards in progress (command 56); block delete of
users (command 58)

Bi-color LED

Steady red

Lock is locked

Steady green

Lock is energized (timed or latched)

Quick double red/green fl ash

Prox card read correctly

All LED's

Rapid red, yellow, green
sequencing

Power on/reset

Sounder
(system)

Very quick beep (10 ms) with
yellow LED blink every second

EEPROM read error during get system parameters; can be turned
off by running self-test

3 slow beeps (250 ms)

Indicates self test

Sounder (after
PIN)

3 rapid beeps after

PIN not found

Sounder (after
card)

3 very rapid beeps

PIN not found, facility code/company ID mismatch and access by
facility mode enabled; incorrect card type (option #20)

1 short beep

Valid card access

Secured Series Front End Mode Default Settings

Option

Default Setting

Option

Default Setting

Master Code

1234

Audio Keypress Feedback

Enabled

Visual Keypress Feedback

Enabled

Auto-Entry

Disabled

Anti-Passback

Enabled

Reader In/Out Select

In

Keypad In/Out Select

In

Prox Card Type

26-bit

Facility Match Required

Disabled

Facility Code

1

Corporate 1000 ID

4095