Maintenance

Maintenance Schedule

E

VERY

T

HREE

M

ONTHS

Inspect belt for wear, tension, and cracking.

Check all screws and bolts to confirm that are tight per assembly instructions.

Inspect bolts and hardware for breakage.

E

VERY

S

IX

M

ONTHS

Check connecting control and all cables for degradation from environment

and use. If necessary, replace per safety per local electrical codes.

E

VERY

T

WELVE

M

ONTHS

Use high-grade silicone grease on all carrier rollers.

Replacement and Optional Parts

ETS-Lindgren may substitute a similar part or new part number with the same

functionality for another part/part number. Contact ETS-Lindgren for questions

about part numbers and ordering parts.

Following are the part numbers for ordering replacement or optional parts for the

Model 2171B/2170B.

Part Description

Part Number

Boresight links

3-meter link

5-meter link

10-meter link

119612

119613

119614

Non-boresight link

1 1/2-in link

1-in link

Cam knob

Cam lock knob

118050

118051

118052

118059

Offset boom, 2171B/2170B

118617

Timing Belt (33 ft required)

880393

Fuse, 5 x 20mm 3A Slow

480029