Additional Installation and Adjustments

|

43

Install Boresight Links and Level Carrier (2171B Only)

Install only one set of boresight links at a time.

Never operate the Model 2171B with boresight and non-boresight links installed at the same time.

I

NSTALL

B

ORESIGHT

L

INKS

Each boresight link has a pattern of holes that identifies the

type of testing it is used to perform. The 3-m link has a

3-hole pattern, the 5-m link a 5-hole pattern, and the

10-m link a 10-hole-pattern; the carrier includes a

corresponding pattern of holes indicating the correct

installation location for each.

To install a set of boresight links, match the hole pattern on

the links with the hole pattern on the carrier, remove the cam

pin, bushings, and knobs, install the desired links, and then

replace pin, bushings, and knobs.

The hole patterns on the carrier match

the hole patterns on the links