Weep-holes-typeb – Oldcastle BuildingEnvelope ICR-225 User Manual

Page 21

Advertising
background image






18

March 2012

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

I C R - 2 2 5 - I N S T A L L A T I O N M A N U A L

FRAME FABRICATION TYPE “B”

Weep Holes

Figure 18

HP-1004

Baffle

SPW-295

Horizontal

Head

5/16” Dia. Weep Hole @ 1/4 points

of ea. Lite; (Typical at Horiz. and

Sill and incidental Water Head)

NOTE: Weep

required at Head

for incidental

water only!

Baffle Retainer

ICW-12 Clip typical

ICR- 312 Baffle Clip @

incidental Water Head

Sill

ICR- 312 Baffle

Clip @ Weeps

5.4 Install ICW-12 Isolator Clips on all vertical and horizontal framing members at 12” o.c. Stagger the clips by

approximately 2” at ends and 6” at intermediate clips.

See Figure 18 . ICR-312 isolator clips/baffles must be

installed over each weep hole at the head or horizontals. Once clips are installed, snap face caps into position.

The vertical caps should be installed first, then horizontal, head and sill caps.