Figure 32

Head anchor (Do Not

pre-install onto

building)

Install 6” reinforcing sleeve

prior to attaching Mullion

sleeve located at Head anchor

(see Detail A for location)

Access holes

Vertical attachment

screw beyond

Vertical Mullion

Vertical attachment screw.

Fasten through reinforcing

sleeve

Install 8” reinforcing sleeve

prior to attaching Mullions.

Sleeve located at Vertical

Mullion connections. (See

Detail “A” for location)

Head and Sill Reinforcing Sleeves (6” System)

Refer to approved

shop drawings

Head anchor

Head reinforcing

sleeve

Refer to approved

shop drawings

Seal reinforcing

sleeve