I C R - 2 2 5 - I N S T A L L A T I O N M A N U A L

Figure 29

Side Block Installation

GP-125 “W” Block

Temporary Wedge Gasket

Expanded “W” Block

(See view at left)

GP-140 Side Block at shallow pocket

(install before glass is set)

8.4

Install side blocks in vertical mullions as required.

SEE FIGURE 29. Consult glass manufacturer for

preferred location in seismic areas.

NOTE: Side Blocks are optional and not required at SSG

Mullions.

8.5

Install glass stops and run interior wedge, crowding into corners. Seal corners of wedge gaskets at

the bottom of each lite after all gaskets have been installed. Wedge should be allowed to relax and

cut long as described in

STEP 8.1 page 24.

SIDE BLOCK INSTALLATION