Troubleshooting – Vinten Radamec Fusion FHR-120 User Manual

Page 36

Advertising
background image

Fusion FHR-120 robotic pan and tilt heads

34

Troubleshooting

Fault

Check

See

Power supplied, but the
camera cradle is not
moving.

Check that the camera cradle lock is
disengaged.

Locking the camera
cradle
on page 29

Head not operating.

Check that the power switch is ON.

Powering up on
page 29

Ensure that the power and Ethernet
cables are connected and secure.

Power and Ethernet
connections
on
page 20

Check power supply to head. Check that
power is being supplied from the
pedestal, height drive or studio supply.

Check the head fuses and replace as
necessary. The head requires two T6.3A
fuses.

Changing a fuse on
page 33

Camera and payload
moving too far on the
pan and tilt axis.

Check the pan and tilt limits using the
Fusion Setup and Test configuration
software tool.

Setting the pan and
tilt movement limits

on page 26