For more information about requirements for installing eomponents in a гаек, see the Dell
Raek Advisor software available on the Dell website at http://support.dell.com.

/t\ CAUTION: If you are installing more than one system, install the slide

assemblies so that the first system is installed in the lowest available position in

the rack.

To mark the raek, perform the following steps:

1

Plaee a mark on the raek’s front vertieal rails where you want to loeate the bottom of

the system you are installing in the raek eabinet.

The bottom of eaeh 1-U spaee is at the middle of the narrowest metal area between

holes (marked with a horizontal line on some raek eabinets—see Figure 1-3).

2

Plaee a mark 9.9 eentimeters (1.75 inehes) above the original mark you made (or eount

up three holes in a raek that meets EIA-310 standards) and mark the raek’s front
vertieal rails with a felt-tipped marker or masking tape (if you eounted holes, plaee a
mark just above the top hole). This mark or pieee of tape indieates where the system’s
upper edge will be loeated on the vertieal rails (see Figure 1-9).

R a c k I n s t a l l a t i o n G u i d e |

1 - 9