Installing the Inner Rails

To install the inner rails to the sides of the system, perform the following steps.

CAUTION: The system may be heavy when fully loaded. To prevent personal

injury, do not attempt to move the system by yourself.

1

Position the inner rail on the side of the system ehassis (see Figure 1-7).

Seeure eaeh inner rail to the side of the ehassis with three 10-24 x 0.375-ineh pan-head

Phillips serews (see Figure 1-7).

Seeure eaeh front mounting braeket to the front-left and front-right sides of the

ehassis using two M3 x 4-millimeter pan-head Phillips serews (see Figure 1-7).

Eaeh front mounting braeket is stamped with L (for left) or R (for right) to indieate on
whieh side of the ehassis (as viewed from the front) you are to install eaeh braeket.

F i g u r e 1 - 7 . I n s t a l l i n g t h e I n n e r R a i l s

R a c k I n s t a l l a t i o n G u i d e

|