COOLING FLOW

MK-101

TROUBleSHOOTiNG

(A)

Check cooling flow Adjusting

Clamp open

(B)

Remove the Cooling Transfer

Tube from the Blade Guard inlet

(C)

Place Pump into a bucket of

water and check flow

(D)

Remove the Cooling Transfer

Tube and check flow

(E)

Inspect and clean pump. See

pump manual

(F)

Remove the Blade Guard In-

take Fitting and check

"Rodding" cooling channels is performed by inserting a small wire rod through the

cooling inlet on top of the Blade Guard and directing the rod out through each of the

cooling flow tubes located on the underside of the Blade Guard. The cooling channels

should be "rodded" until all ports are free of foreign debris.

NOTe:

(G)

Remove the Cooling Chan-

nel cover screws

(H)

Rod Cooling Channels and

recheck flow