6-1

Installation and Upgrade Guide for Cisco Unified MeetingPlace Audio Server 6.x

OL-13417-01

6

Maintaining the Cisco Unified MeetingPlace
Audio Server System

This chapter describes how to maintain—not repair—the Cisco Unified MeetingPlace Audio Server
system and contains the following sections:

Replacing the Filter in the Power Supply Unit Fan (Cisco Unified MeetingPlace 8112 Only),
page 6-1

Enabling Server Disk Capacity Monitoring, page 6-3

(For information about repairing the Cisco Unified MeetingPlace Audio Server system, contact
Cisco TAC. See the

“Obtaining Documentation, Obtaining Support, and Security Guidelines” section on

page x

.)

Replacing the Filter in the Power Supply Unit Fan (Cisco Unified
MeetingPlace 8112 Only)

Note

The maintenance procedures in this section are for the Cisco Unified MeetingPlace 8112 only. The Cisco
Unified MeetingPlace 8106 does not have a filter for the fan in the power supply unit.

You need to replace the filter in the power supply unit fan on a regular basis. The frequency of the
replacement depends on how much dust is in the air. On average, you should replace the filter once a
year.

In addition, if you see any of the following alarms, immediately check the power supply unit fan and its
filter:

0x70034 (MAJOR) Temperature out of range.

0x700BB (MINOR) Power supply fan N is failing.

0x700C6 (MINOR) Power supply N cooling failure.

This section contains three procedures. Do them in the order listed to replace the filter.

Do not touch any of the exposed leads, terminals, or components. Hazardous voltages, capable of
causing death, may be present in this product.