PSEN op4F/H-s Series
Instruction Manual
16
It is thus important to position the safety light curtain according to the
minimum distance from reflecting surfaces.
The minimum distance depends on:
•
operating distance between emitter (
TX) and receiver (RX);
•
real aperture angle of AOPD (EAA); especially:
for AOPD type 4 EAA = 5° (α = ± 2,5°)
Diagram of Fig. 8 shows the minimum distance from the reflecting
surface (Dsr), based on the operating distance:
Fig. 8
The formula to get Dsr is the following:
Dsr (m) = 0.15
for oper.distance < di 3 m
Dsr (m) = 0.5 x operating distance (m) x tg 2α
for oper.distance ≥ di 3 m
AOPD
Type 4
Advertising
This manual is related to the following products:
- PSEN op4H-s-30-165/1 PSEN op4H-s-30-090/1 PSEN op4H-s-30-015/1 PSEN op4H-s-30-075/1 PSEN op4H-s-30-045/1 PSEN op4H-s-30-135/1 PSEN op4H-s-30-120/1 PSEN op4H-s-30-180/1 PSEN op4H-s-30-105/1 PSEN op4H-s-30-030/1 PSEN op4F-s-14-180/1 PSEN op4F-s-14-165/1 PSEN op4F-s-14-150/1 PSEN op4F-s-14-135/1 PSEN op4F-s-14-120/1 PSEN op4F-s-14-105/1 PSEN op4F-s-14-090/1 PSEN op4F-s-14-075/1 PSEN op4F-s-14-060/1 PSEN op4F-s-14-045/1 PSEN op4F-s-14-030/1 PSEN op4F-s-14-015/1