Instruction Manual

16

It is thus important to position the safety light curtain according to the

minimum distance from reflecting surfaces.

The minimum distance depends on:

operating distance between emitter (

TX) and receiver (RX);

real aperture angle of AOPD (EAA); especially:

for AOPD type 4 EAA = 5° (α = ± 2,5°)

Diagram of Fig. 8 shows the minimum distance from the reflecting

surface (Dsr), based on the operating distance:

Fig. 8

The formula to get Dsr is the following:

Dsr (m) = 0.15

for oper.distance < di 3 m

Dsr (m) = 0.5 x operating distance (m) x tg 2α

for oper.distance ≥ di 3 m