Pilz PSEN op4H-s-30-150/1 User Manual

Page 61

Advertising
background image

Instruction Manual

PSEN op4F/H-s Series

57

EMITTER: unit emitting infrared beams, consisting of a set of optically-

synchronised LEDs. The emitting unit, combined with the receiving unit

(installed in the opposite position), generates an optical “curtain”,

i.e.

the detecting area.

EXTERNAL DEVICE MONITORING (EDM): device used by the AOPD

to monitor the status of the external command devices.

FINAL SWITCHING DEVICE (FSD): part of the control system

involving machine safety conditions. It breaks the circuit to the

machine primary control element (MPCE) when the output signal

switching device (OSSD) becomes inactive.

FORCE-GUIDED CONTACTS: Contacts can be guided forcibly when

they are connected mechanically so that they can switch

simultaneously, when the input stage is active.

If one contact of the series remains “hanged”, no other relay contact is

able to move.

This function allows the control of the EDM status.

MACHINE OPERATOR: qualified person allowed to use the machine.

MACHINE PRIMARY CONTROL ELEMENT (MPCE): electrically-

powered element having the direct control of machine regular

operation so as to be the last element, in order of time, to operate

when the machine has to be enabled or blocked.

MIN. INSTALLATION DISTANCE: min. distance necessary to allow

machine dangerous moving parts to completely stop before the

operator can reach the nearest dangerous point. This distance shall be

measured from the middle point of the detecting area to the nearest

dangerous point. Factors affecting min. installation distance value are

machine stop time, total safety system response time and light curtain

resolution.

N.O.: normally opened

N.C.: normally closed

OFF STATUS: status when the output circuit is interrupted and does

not allow current stream.

ON STATUS: status when the output circuit is operational and allows

current stream.