PSEN op4F/H-s Series

Instruction Manual

32


The ground connection of the two units is not necessary for Class

III, while the use of a duly-insulated low-voltage feeder type SELV

or PELV is compulsory. In this case, we recommend covering the

earth symbol present on the caps of the two units with a blank

sticker.

The ground connection of the two units is compulsory for Class I,

while the use of a duly-insulated feeder type SELV or PELV is not

compulsory but anyway recommended.

The following table is a summary of PSEN op4F/H-s electrical

protections.

Electrical protections

Class I

Class III

Ground Connection

Compulsory

Forbidden

Ground connection symbol

Compulsory

Forbidden

Power supply by generators

SELV / PELV

Recommended

Compulsory