The ground connection of the two units is not necessary for Class
III, while the use of a duly-insulated low-voltage feeder type SELV
or PELV is compulsory. In this case, we recommend covering the
earth symbol present on the caps of the two units with a blank
sticker.
•
The ground connection of the two units is compulsory for Class I,
while the use of a duly-insulated feeder type SELV or PELV is not
compulsory but anyway recommended.
The following table is a summary of PSEN op4F/H-s electrical
protections.
Electrical protections
Class I
Class III
Ground Connection
Compulsory
Forbidden
Ground connection symbol
Compulsory
Forbidden
Power supply by generators
SELV / PELV
Recommended
Compulsory
- PSEN op4H-s-30-165/1 PSEN op4H-s-30-090/1 PSEN op4H-s-30-015/1 PSEN op4H-s-30-075/1 PSEN op4H-s-30-045/1 PSEN op4H-s-30-135/1 PSEN op4H-s-30-120/1 PSEN op4H-s-30-180/1 PSEN op4H-s-30-105/1 PSEN op4H-s-30-030/1 PSEN op4F-s-14-180/1 PSEN op4F-s-14-165/1 PSEN op4F-s-14-150/1 PSEN op4F-s-14-135/1 PSEN op4F-s-14-120/1 PSEN op4F-s-14-105/1 PSEN op4F-s-14-090/1 PSEN op4F-s-14-075/1 PSEN op4F-s-14-060/1 PSEN op4F-s-14-045/1 PSEN op4F-s-14-030/1 PSEN op4F-s-14-015/1