Fig. 12


AOPD has to be correctly aligned, press slightly on the product side

in both directions the red LED must not turn on

.

The activation of the TEST function (optional for the safety light

curtains Type 4) causes the opening of the OSSD outputs (red LED

on and controlled machine stop).

The response time at machine STOP, including the AOPD and

machine response times, must be included in the limits defined in

the calculation of the safety distance (refer to section 2 “Installation

modes”).

The safety distance between the dangerous parts and AOPD must

comply with the requirements indicated in section 2 “Installation

modes”.

A person must not access or remain between AOPD and the

dangerous parts of the machine.

Access to the dangerous areas of the machine must not be

possible from any unprotected area.

AOPD must not be disturbed by external light sources, ensuring

that it remains in Normal operating function for at least 10-15

minutes and placing the specific test piece in the protected area in

the SAFE condition for the same period.

Verify the correspondence of all the accessory functions, activating

them in the different operating conditions.