Pilz PSEN op4H-s-30-150/1 User Manual
Page 26

PSEN op4F/H-s Series
Instruction Manual
22
Fig. 12
•
AOPD has to be correctly aligned, press slightly on the product side
in both directions the red LED must not turn on
.
•
The activation of the TEST function (optional for the safety light
curtains Type 4) causes the opening of the OSSD outputs (red LED
on and controlled machine stop).
•
The response time at machine STOP, including the AOPD and
machine response times, must be included in the limits defined in
the calculation of the safety distance (refer to section 2 “Installation
modes”).
•
The safety distance between the dangerous parts and AOPD must
comply with the requirements indicated in section 2 “Installation
modes”.
•
A person must not access or remain between AOPD and the
dangerous parts of the machine.
•
Access to the dangerous areas of the machine must not be
possible from any unprotected area.
•
AOPD must not be disturbed by external light sources, ensuring
that it remains in Normal operating function for at least 10-15
minutes and placing the specific test piece in the protected area in
the SAFE condition for the same period.
•
Verify the correspondence of all the accessory functions, activating
them in the different operating conditions.
- PSEN op4H-s-30-165/1 PSEN op4H-s-30-090/1 PSEN op4H-s-30-015/1 PSEN op4H-s-30-075/1 PSEN op4H-s-30-045/1 PSEN op4H-s-30-135/1 PSEN op4H-s-30-120/1 PSEN op4H-s-30-180/1 PSEN op4H-s-30-105/1 PSEN op4H-s-30-030/1 PSEN op4F-s-14-180/1 PSEN op4F-s-14-165/1 PSEN op4F-s-14-150/1 PSEN op4F-s-14-135/1 PSEN op4F-s-14-120/1 PSEN op4F-s-14-105/1 PSEN op4F-s-14-090/1 PSEN op4F-s-14-075/1 PSEN op4F-s-14-060/1 PSEN op4F-s-14-045/1 PSEN op4F-s-14-030/1 PSEN op4F-s-14-015/1