Wilbur Curtis EXPR User Manual

Service manual – expressions multi-flavor, Ilbur, Urtis

Advertising
background image

1

NSF International requires the following water connection:

1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so

that the unit can be moved for cleaning.

2. This unit must be installed with adequate backflow protection to comply with applicable federal,

state and local codes.

3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized,

installed and maintained in accordance with federal, state, and local codes.

Symbols

WARNINGS – To help avoid personal injury

Important Notes/Cautions – from the factory

Sanitation Requirements

Service Manual – Expressions Multi-flavor

This Curtis Generation 3 Unit is Factory Pre-Set and Ready to Go Right from the Box.

Following are the Factory Settings for your Expressions Multi-flavor Beverage System:

• Tank Temperature = 190°F

• Dispensing Mode Set for Manual Dispense

Generally there will never be a reason to change your G3 programming. However, should you need

to make slight adjustments to meet your dispensing needs, programming instructions are provided

later in this manual.

System Requirements:

• Water Source 20 – 90 PSI (Minimum Flow Rate of 1 GPM)

• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for

your model.

W

ilbur

C

urtis

C

ompany

, i

nC

.

Important Safeguards/Symbols

CAUTION: DO NOT

connect this unit to

hot water. Inlet valve

not rated for hot water.

CAUTION: Use this

setup procedure

before attempting

to use this appliance. Failure

to follow the instructions can

result in injury or the voiding
of the warranty.

WARNING HOT

LIQUID, Scalding

may occur. Avoid

splashing.

Model Included:

■ EXPR

ISO 9001:2008 REGISTERED

WILBUR CURTIS CO.

Montebello, CA 90640

For the latest information go to

www.wilburcurtis.com

Tel: 800/421-6150

This equipment is designed for commercial use. Any servicing other than cleaning and routine

maintenance should be performed by an authorized Wilbur Curtis Company Service Technician.

• DO NOT immerse the unit in water or any other liquid

• To reduce the risk of fire or electric shock, DO NOT open service panels. There are no

user serviceable parts inside.

• Keep hands and other items away from hot areas of the unit during operation.

• Never clean with scouring powders or harsh chemicals.

3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the ‘ON’ position (located on the rear of

the unit), the water tank will begin to fill. When the water level in the tank reaches the probe, the heating

element(s) will turn on.

5. Water in the heating tank will require approximately one hour before reaching operating temperature (factory

setting of 190°F). Where applicable, turn on the Universal Control Module (UCM). When the unit reaches

operating temperature, it will display “READY TO BREW”.

NOTE: A water filtration system must be used to help maintain trouble-free operation. Air must be purged

from the cartridge prior to connection to equipment. In areas with extremely hard water, we highly

recommend the use of a Curtis approved water filter. For our full line of filters, please log on to www.wilbur-

curtis.com.

SETUP STEPS

1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine

should be consistent. Use tubing sized sufficiently to provide a minimum flow rate of one gallon per minute.