3 calculating fiber link attenuation, 35 figure 6-2. measuring receiver input power, Check optical power levels – CANOGA PERKINS 9145EMP Network Interface Device Hardware User Manual

Page 47

Advertising
background image

Maintenance

9145EMP Network Interface Device Hardware User’s Manual

Check Optical Power Levels

35

Figure 6-2. Measuring Receiver Input Power

6.2.3 Calculating Fiber Link Attenuation

Link attenuation measurement identifies potential problems with links that are on the threshold of
receiver sensitivity. Measure optical fiber links at the shortest wavelength of operation, as it is the
limiting factor in the loss budget. Use a power meter calibrated for the laser source, then factor in
approximately 1 dB for the connector loss from the patch cables between the 9145EMP and the
local device. (Each fiber connection can generate 0.5 dB of additional loss.)

NOTE: If you cannot determine the Rx sensitivity, contact Canoga Perkins Techni-

cal Support for assistance.

Follow these steps to calculate fiber link attenuation:

1. Determine transmitter output power as described in paragraph 6.2.1 above.

2. Determine receiver input power as described in paragraph 6.2.2 above.

3. Subtract receiver input power from transmitter output power. The result is the fiber link

attenuation.

Transmit Output Power

-7.0 dBm

Receiver Input Power

-28.2 dBm

Fiber Link Attenuation

21.2 dB

FIBER OPTIC

TRANSMITTER

FIBER OPTIC

RECEIVER

OPT

IC
A

L

P
O

WE

R

ME

TER

-2
4

dB
m

λ

= 1

300

nm

FIBER OPTIC

TRANSMITTER

FIBER OPTIC

RECEIVER

OPT

IC

A

L

P

O

WE

R

ME

TER

-2

4

dB

m

λ

= 1

300

nm

LOCAL SITE

REMOTE SITE

Advertising