Recalling the constant, Recall last measured value (stack), Tracking - minimum – Leica Geosystems Leica DISTO plus - Manual User Manual
Page 8: Tracking - maximum
![background image](/manuals/651794/8/background.png)
7
1st Function level
Leica DISTO™ plus 1.0.0 GB
de
GB
fr
it
es
nl
ja
starts to blink on the display.
With key [+ / -] adjust value as desired (e.g. from 2.297m
to 2.300m).
For larger steps press and hold additionally.
Press to adjust unit (²/³).
)
The adjustment is for m, m² and m³ rsp. ft, ft² and
ft³ only.
Confirm.
and a number (=memory location) starts to blink.
With key [+ / -] select memory location (1-10).
Save value.
Recalling the constant
Briefly press.
and the contents of the first constant memory
location are displayed (e.g. 2.300m).
With key [+ / -] select desired mermory (1 to 10).
Confirm; value is ready to be used for (e.g.
calculating an area) or
Recall last measured value (Stack)
Briefly press twice
and the last value in the display is shown.
With key [+ / -] select desired value (max. 15!).
Confirm; value is ready to be used for (e.g.
calculating an area).
Tracking - Minimum
D5-Z11
Determine the minimum dimension, e.g. ceiling height,
without having to precisely align to the normal.
Press until
appears on the display.
Aim Leica DISTO™ plus approximately at the target point.
Activate continuos measurement with a brief
press.
Move the Leica DISTO™ plus a large amount around the
target point.
Stop continuous measurement.
The smallest measurement is displayed (e.g. 3.215m =
height of room).
)
Both planes (e.g. floor/ ceiling, walls) must be
nearly parallel to each other.
Tracking - Maximum
D5-Z12